EFORT open reviews | 2016 | Docquier PL, Paul L, TranDuy K
Journal and index pages often block iframe embedding. This reader keeps the evidence details in Orthonotes and leaves the source page one click away.
Conflict of interest statement: Conflict of Interest: Paul Laurent and Khanh TranDuy are founders of 3D Side, a patient-specific surgical technology manufacturer. 19. Foot Ankle Int. 2023 Nov;44(11):1150-1157. doi: 10.1177/10711007231194049. Epub 2023 Sep 20. Accuracy of a Patient-Specific Total Ankle Arthroplasty Instrumentation. April PM(1), Locke E(1), Champagne PH(2), Angers M(2), Martinez-Gomez AP(1), Seidel A(1), Jibri Z(1), Lalonde KA(1), Meulenkamp B(1). Author information: (1)Department of Orthopaedics, Civic Hospital, Ottawa, Canada. (2)Department of Orthopaedics, CHUS, Sherbrooke, Canada. Comment on Foot Ankle Int. 2021 May;42(5):616-623. doi: 10.1177/1071100720972664. BACKGROUND: Total ankle arthroplasty (TAA) is a preferred surgical option for end-stage ankle osteoarthritis; however, it is a demanding procedure with a higher historical rate of revision compared with ankle fusion. Patient-specific instrumentation (PSI) has been introduced to optimize prosthesis alignment and theoretically overall improve TAA outcomes. The goal of this study is to report on the experience and surgical outcomes of one implant with specific evaluation of the accuracy and reproducibility of the system with respect to prosthesis alignment and prediction of implant size. METHODS: A retrospective, multicentered study involving 4 foot and ankle fellowship-trained orthopaedic surgeon's patients undergoing TAA between January 1, 2015, and December 31, 2018, using the PROPHECY PSI system. RESULTS: 80 TAA procedures were performed. On average the postoperative tibial component alignment was 89.9 (range, 86.1-96.5) degrees in the coronal plane, with a mean sagittal alignment of 88.1 (range, 81.3-96.7) degrees. The mean deviation from neutral sagittal alignment improved from 4.9 ± 3.9 degrees preoperatively to 2.7 ± 1.7 degrees postoperatively, whereas the mean coronal alignment improved from 3.3 ± 2.5 degrees to 1.3 ± 1.1 degrees. The PSI software correctly determined the tibial implant size in 70 patients (89%). Prediction of talar implant sizing was less accurate than the tibial component, with 56 patients (71%) using the predicted sized implant. The overall implant survival at a mean follow-up of 45 months (range, 27-76) was 97.5%. CONCLUSION: We found that this PSI system accurately and reliably assisted in implant total ankle prosthesis positioning within a clinically acceptable margin and without significant outliers. Prediction of implant size was not as accurate as component orientation. LEVEL OF EVIDENCE: Level III, retrospective study. DOI: 10.1177/10711007231194049
This article has not been linked to a wiki topic yet.
This article has not been linked to a case yet.
This article has not been linked to an atlas yet.