Orthonotes
Orthonotes
by the.bonestories
v3.0 Fusion
v3.0 Fusion
PubMed Narrative Review Evidence Moderate

Diagnosis of acute compartment syndrome: current diagnostic parameters.

Injury | 2025 | Bouklouch Y, Miclau T, Harvey E

In-App Reader

Open Source

Journal and index pages often block iframe embedding. This reader keeps the evidence details in Orthonotes and leaves the source page one click away.

Source
PubMed
Type
Narrative Review
Evidence
Moderate

Abstract

[Indexed for MEDLINE] Conflict of interest statement: Declaration of competing interest This paper is part of a Supplement supported by The Osteosynthesis and Trauma Care Foundation (OTCF), which receives funding from the Stryker Corporation. 13. J Orthop Trauma. 2025 Apr 8. doi: 10.1097/BOT.0000000000002980. Online ahead of print. Clinical trial of a new continuous compartment pressure monitoring to aid in the diagnosis of Acute Compartment Syndrome. Balhareth MA(1), Vaile K(1), Schneider P(2), Liew A(3), Hall J(4), Guy P(5), Lawendy AR(6), Doornberg J(7), Jaarsma R(8), Leighton R(9). Author information: (1)Arthroplasty and Trauma Fellow QE II HSC, HI Site, Halifax Nova Scotia, B3H3A7 Dr.balhareth@hotmail.com. (2)University of Calgary 2500UniversityDrive NM Calgary Alberta,T2N1N4 Prism.schneider@albertahealthservices.ca. (3)Assistant professor Room 1053 Carling Avenue, Suite J 35 Ottawa On, K1Y4E9 aliew@ottawahospital.om.ca. (4)St Michael's Hospital 55Queen street east Toronto, ON, M5C1R6 Jeremy .Hall @unityhealth.to. (5)Professor and head of Division of Orthopedic trauma University of British Columbia Vancouver general Hospital Pierre.guy@ubc.ca. (6)Chief Orthopedic Trauma Service Department of Surgery Western University Abdelrahman.lawendy@ihsc.on.ca. (7)University of Groningen Amsterdam, Noord -Holland, Nederland jobdoornbergortho@gmail.com. (8)Clinical Director of orthopedic at Flinders Medical Centre and Flinders University Adelaide Australia Ruurd.Jaarsma@sa.gov.au. (9)Professor of Surgery Dalhousie University 1796 Summer Street, Suite 4875 Hi Site QE II HSC Halifax, N.S. Canada, B3H3A7 Phone 1-902-473-4035 Fax -1-902-473-4490 Email----leightonr2@gmail.com. OBJECTIVES: To evaluate a new compartment pressure monitor reporting continuous pressures and its contribution to Acute Compartment Syndrome (ACS) diagnosis. METHODS: Design: Multicenter, non-randomized, prospective study. SETTING: Six Level-I Trauma Centers. PATIENT SELECTION CRITERIA: Enrolled were patients with acute long bone fractures (OTA 11-13, 2R, 2U, 31-33, and 41-43) where the Micro Electric Mechanical Sensor (MEMS) device was inserted either pre- or post-operatively into the compartment most likely to develop ACS, as deemed by the surgeon. Intracompartmental pressures (ICP) were continuously measured for up to 18 hours (as indicated by the FDA and Health Canada); clinical signs were simultaneously assessed for canonical compartment syndrome signs. OUTCOME MEASURES AND COMPARISONS: The primary measurement outcomes were ease of use, accuracy, and safety of the device across all participating sites. Ease of use was assessed through surveys completed by surgeons, which evaluated their confidence in the device's functionality and usability. Accuracy was determined by analyzing patient outcomes, using surgical findings and clinical resolution as the gold standards, to assess whether the device's results corresponded to true positive and true negative cases of compartment syndrome. Feasibility was defined as the device's ability to integrate into the clinical workflow, operate reliably under typical conditions, and provide actionable data for ACS diagnosis. The secondary outcomes included continuous intracompartmental pressure (ICP) measurements and their diagnostic value. Sensitivity and specificity were evaluated by comparing continuous ICP data with clinical assessments based on the "6 P's" (pain, pallor, paresthesia, pulselessness, poikilothermia, and paralysis) to determine their combined utility in diagnosing ACS. RESULTS: A total of 100 patients, 68 males and 32 females with an average age of 42 years old (17-80 years old), were enrolled. All of the patients had suffered a fracture, 25 proximal tibias (OTA/AO-41), 40 midshaft tibias (OTA/AO42), 13 distal tibias (OTA/AO43), 11 forearms (OTA/AO 2R.2U), 6 femurs (OTA/AO31-33), 5 humerus (OTA/AO 11-13). Eighty-nine patients received the MEMS device post-operatively and 11 patients pre-operatively. 93% of participating surgeons reported confidence in the device's function and ease of use. Pressures were measured on average for 16h36 (3h-18h). No complications were reported. Post-operative ICPs (25.4 mmHg) were higher (p =0.0462) on average than pre-operative ICPs (18.9 mmHg). Patients that did not develop Compartment Syndrome had their post-operative pressures trend down after 4 hours (23.8mmHg). Sensitivity and specificity analyses of ICP alone, delta P alone, pressure trends alone, or a combination of the three metrics were conducted using patient outcomes as the gold standard for diagnostic accuracy. The trend of the curve in continuous monitoring pressure measurements proved more reliable than a single absolute pressure value in aiding in the correct diagnosis of ACS deviating from standard ACS diagnosis literature The MEMS device allowed earlier diagnosis of ACS by 4 hours (. When continuous pressure measurement was combined with standard clinical examination, the sensitivity and specificity reached 100%. CONCLUSIONS: The MEMS-based device reliably enabled continuous compartment pressure monitoring in all the study institutions. Further examination of continuous trends and accompanying perfusion pressure could allow surgeons the clinical adjunct to diagnose ACS many hours earlier than clinical signs alone. LEVEL OF EVIDENCE: Level II - Prospective study. Copyright © 2025 Wolters Kluwer Health, Inc. All rights reserved. DOI: 10.1097/BOT.0000000000002980

Linked Wiki Topics

This article has not been linked to a wiki topic yet.

Linked Cases

This article has not been linked to a case yet.

Linked Atlases

This article has not been linked to an atlas yet.