Orthonotes
Orthonotes
by the.bonestories
v3.0 Fusion
v3.0 Fusion
Crossref Journal Article Evidence Unclassified

Medial Plating of Pauwels Type III Femoral Neck Fractures Decreases Shear and Angular Displacement Compared with a Derotational Screw

Journal of Orthopaedic Trauma | 2020 | Chima D. Nwankwo, Patrick Schimoler, Victor Greco, Alexander Kharlamov

In-App Reader

Open Source

Journal and index pages often block iframe embedding. This reader keeps the evidence details in Orthonotes and leaves the source page one click away.

Source
Crossref
Type
Journal Article
Evidence
Unclassified

Abstract

Objectives: The purpose of this mechanical study was to compare 2 methods of augmented stabilization of Pauwels type III femoral neck fractures. Methods: Ten matched pairs of young cadaveric femurs were cut 22 cm distal to the lesser trochanter. All specimens received a 70-degree osteotomy, which was stabilized with a 135-degree sliding hip screw. One of each pair received augmented fixation with a 6.5 mm fully threaded cannulated screw. The other specimen in the matched pair had additional fixation with a 3.5 mm 5-hole tubular plate placed at the inferior-medial femoral neck. Each specimen was tested under cyclic axial loading conditions (5000 cycles between 200 and 1400 N at 2 cycles/sec) and subsequently loaded to failure. The angular displacement (varus), interfragmentary (shear) displacement, and failure loads were calculated. Results: In the augmented plate group, 7 specimens failed by angular displacement and 3 failed by shear displacement. In the augmented screw group, 8 specimens failed by angular displacement and 2 by shear displacement. The plate group was found to have significantly less angular displacement, regardless of completed cycles, than the augmented screw group (0.75 ± 0.35 degrees vs. 2.15 ± 1.99 degrees averaged across completed cycles, P < 0.01). Similarly, the plate group was found to have significantly less shear displacement, regardless of completed cycles, than the augmented screw group (0.77 ± 0.70 mm vs. 1.22 ± 0.92 mm averaged across completed cycles, P = 0.01). The average failure load of the plate group (4930 ± 1578 N) was also larger but not significantly different from the screw group (3824 ± 2140 N), P = 0.12. Conclusions: Augmenting sliding hip screw stabilization of a Pauwels type III fracture with a medial plate applied to the femoral neck significantly decreases angular displacement and shear displacement compared with augmentation with a derotational screw.

Linked Wiki Topics

This article has not been linked to a wiki topic yet.

Linked Cases

This article has not been linked to a case yet.

Linked Atlases

This article has not been linked to an atlas yet.