Acta orthopaedica Belgica | 2020 | Wautier D, Ftaïta S, Thienpont E
Journal and index pages often block iframe embedding. This reader keeps the evidence details in Orthonotes and leaves the source page one click away.
[Indexed for MEDLINE] 15. J Knee Surg. 2023 Mar;36(4):411-416. doi: 10.1055/s-0041-1735279. Epub 2021 Sep 10. Radiographic Findings in Flexion Instability after Total Knee Arthroplasty. Howie CM(1), Mears SC(1), Barnes CL(1), Mannen EM(1)(2), Stambough JB(1). Author information: (1)Department of Orthopaedic Surgery, University of Arkansas for Medical Sciences, Little Rock, Arkansas. (2)Department of Mechanical and Biomedical Engineering, Boise State University, Boise, Idaho. Flexion instability (FI) is one of the leading causes of knee pain and revision surgery. Generally, the biomechanical etiology is considered to be a larger flexion than extension gap. This may be due to mismatch of components sizes to the bone or malalignment. Other factors such as muscle weakness may also play a role, and the diagnosis of FI after total knee arthroplasty (TKA) relies on a combination of patient's complaints during stair descent or walking and physical examination findings. Our study examines the role of implant positioning and sizes in the diagnosis of FI. A retrospective review of 20 subjects without perceived FI and 13 patients diagnosed with FI after TKA was conducted. Knee injury and osteoarthritis outcome scores (KOOS) were documented, and postoperative radiographs were examined. Measurements including included tibial slope, condylar offset, femoral joint line elevation along with surrogate soft-tissue measures for girth and were compared between groups. The FI group was found to have a significantly lower KOOS score compared with the non-FI group (55.6 vs. 73.5; p = 0.009) as well as smaller soft-tissue measurements over the pretubercle region (6.0 mm vs. 10.6 mm; p = 0.007). Tibial slope, condylar offset ratios, and femoral joint line elevation were not significantly different between the FI and non-FI groups. We noted a significant difference in tibial slope in posterior-stabilized implants in subjects with and without FI (6.4° vs. 1.5°; p = 0.003). Radiographic measurements consistent with malalignment were not indicative of FI. X-ray measurements alone are not sufficient to conclude FI as patient symptoms, and clinical examinations remain the key indicators for diagnosis. Radiographic findings may aid in surgeon determination of an underlying cause for an already identified FI situation and help in planning revision surgery. Thieme. All rights reserved. DOI: 10.1055/s-0041-1735279
This article has not been linked to a wiki topic yet.
This article has not been linked to a case yet.
This article has not been linked to an atlas yet.